-- CE3804G.ADA -- Grant of Unlimited Rights -- -- Under contracts F33600-87-D-0337, F33600-84-D-0280, MDA903-79-C-0687, -- F08630-91-C-0015, and DCA100-97-D-0025, the U.S. Government obtained -- unlimited rights in the software and documentation contained herein. -- Unlimited rights are defined in DFAR 252.227-7013(a)(19). By making -- this public release, the Government intends to confer upon all -- recipients unlimited rights equal to those held by the Government. -- These rights include rights to use, duplicate, release or disclose the -- released technical data and computer software in whole or in part, in -- any manner and for any purpose whatsoever, and to have or permit others -- to do so. -- -- DISCLAIMER -- -- ALL MATERIALS OR INFORMATION HEREIN RELEASED, MADE AVAILABLE OR -- DISCLOSED ARE AS IS. THE GOVERNMENT MAKES NO EXPRESS OR IMPLIED -- WARRANTY AS TO ANY MATTER WHATSOEVER, INCLUDING THE CONDITIONS OF THE -- SOFTWARE, DOCUMENTATION OR OTHER INFORMATION RELEASED, MADE AVAILABLE -- OR DISCLOSED, OR THE OWNERSHIP, MERCHANTABILITY, OR FITNESS FOR A -- PARTICULAR PURPOSE OF SAID MATERIAL. --* -- OBJECTIVE: -- CHECK THAT FLOAT_IO GET WHEN SUPPLIED WITH A WIDTH PARAMETER -- GREATER THAN ZERO READS ONLY THAT MANY CHARACTERS. ALSO CHECK -- THAT INPUT TERMINATES WHEN A LINE TERMINATOR IS ENCOUNTERED AND -- THAT DATA_ERROR IS RAISED WHEN THE DATA IS INVALID. -- APPLICABILITY CRITERIA: -- THIS TEST IS APPLICABLE ONLY TO IMPLEMENTATIONS WHICH -- SUPPORT TEXT FILES. -- HISTORY: -- SPS 09/08/82 -- SPS 12/14/82 -- VKG 01/13/83 -- SPS 02/08/83 -- JBG 02/22/84 CHANGED TO .ADA TEST -- RJW 11/04/86 REVISED TEST TO OUTPUT A NON_APPLICABLE -- RESULT WHEN FILES ARE NOT SUPPORTED. -- DWC 09/14/87 SPLIT CASE FOR FIXED_IO INTO CE3804H.ADA AND -- CORRECTED EXCEPTION HANDLING. -- LDC 06/01/88 CHANGED TEST VALUE FROM "3.525" TO "3.625". WITH REPORT; USE REPORT; WITH TEXT_IO; USE TEXT_IO; PROCEDURE CE3804G IS INCOMPLETE : EXCEPTION; BEGIN TEST ("CE3804G", "CHECK THAT FLOAT_IO GET WHEN SUPPLIED WITH " & "A WIDTH PARAMETER GREATER THAN ZERO READS " & "ONLY THAT MANY CHARACTERS. ALSO CHECK THAT " & "INPUT TERMINATES WHEN A LINE TERMINATOR IS " & "ENCOUNTERED AND THAT DATA_ERROR IS RAISED " & "WHEN THE DATA IS INVALID."); DECLARE FT : FILE_TYPE; BEGIN BEGIN CREATE (FT, OUT_FILE, LEGAL_FILE_NAME); EXCEPTION WHEN USE_ERROR => NOT_APPLICABLE ("USE_ERROR RAISED; TEXT CREATE " & "WITH OUT_FILE MODE"); RAISE INCOMPLETE; WHEN NAME_ERROR => NOT_APPLICABLE ("NAME_ERROR RAISED; TEXT CREATE " & "WITH OUT_FILE MODE"); RAISE INCOMPLETE; END; PUT(FT, "3.259.5 8.52"); NEW_LINE (FT); PUT (FT, " "); NEW_LINE (FT); PUT (FT, ASCII.HT & "9.0"); NEW_LINE (FT); PUT (FT, "-3.625"); NEW_LINE (FT); CLOSE (FT); -- BEGIN TEST DECLARE TYPE FL IS DIGITS 4; PACKAGE FL_IO IS NEW FLOAT_IO (FL); USE FL_IO; X : FL; BEGIN BEGIN OPEN (FT, IN_FILE, LEGAL_FILE_NAME); EXCEPTION WHEN USE_ERROR => NOT_APPLICABLE ("USE_ERROR RAISED; TEXT" & "OPEN WITH IN_FILE MODE"); RAISE INCOMPLETE; END; GET (FT, X, 4); IF X /= 3.25 THEN FAILED ("WIDTH CHARACTERS NOT READ - FLOAT"); ELSE GET (FT, X, 3); IF X /= 9.5 THEN FAILED ("WIDTH CHARACTERS NOT READ - " & "FLOAT 2"); ELSE GET (FT, X, 4); IF X /= 8.5 THEN FAILED ("DIDN'T COUNT LEADING BLANKS " & "- FLOAT"); ELSE SKIP_LINE(FT); BEGIN GET (FT, X, 2); FAILED ("DATA_ERROR NOT RAISED - " & "FLOAT"); EXCEPTION WHEN DATA_ERROR => NULL; WHEN OTHERS => FAILED ("WRONG EXCEPTION RAISED" & " - FLOAT"); END; SKIP_LINE(FT); GET (FT, X, 4); IF X /= 9.0 THEN FAILED ("GET WITH WIDTH " & "INCORRECT - 3"); END IF; SKIP_LINE (FT); GET (FT, X, 7); IF X /= -3.625 THEN FAILED ("WIDTH CHARACTERS NOT " & "READ - FLOAT 3"); END IF; END IF; END IF; END IF; BEGIN DELETE (FT); EXCEPTION WHEN USE_ERROR => NULL; END; END; EXCEPTION WHEN INCOMPLETE => NULL; END; RESULT; END CE3804G;